API Plan 61

API Plan 61

Tapped and plugged atmospheric-side connections for purchaser’s use.

A  Connection plugged


Seal chamber details

1  Quench (Q), plugged, metal
2  Drain (D), open connected to metal tubing
3  Flush (F)
5  Seal chamber


Example seal: EagleBurgmann LL9UC single pusher mechanical seal.


P&ID according to API

Key

1  Quench (Q), plugged, metal
2  Drain (D), open connected to metal tubing
4  To collection point

 

Features

  • Normally used for single seals but can be applied for dual seals as well.
  • The ‘Q’ and ‘D’ connections when piped, this plan is converted to Plan 62.
  • The ‘D’ connection can be piped to a drain collection system.

Application

  • On horizontal and vertical pumps as a future provision for Plan 62 or Plan 65

Remarks, checkpoints

  • Ensure that atmospheric side ports are always plugged if not in use as foreign particle entry will cause seal failure.
  • Use metallic plugs or connect the necessary piping by replacing the plastic plugs fitted on the mechanical seal gland plate.

Location, function

  • Atmospheric side
  • Drain

Configurations

1CW-FL, 1CW-FX
 

2CW-CW*, 3CW-FB*, 3CW-BB*, 3CW-FF*

* Remark: The configurations listed for each individual piping plan are to be understood as recommendations including possible utilizations which may also be applied.

 

API 682 4th Edition

Contact us

Follow the direct link to your API 682 4th ed. contact

Show locations

API piping plan tool

Download the free EagleBurgmann API piping plan tool and benefit from useful and practical information

PDF download - 4.0 MB
Newsletter

Excellence in Practice

With our free e-mail newsletter „Excellence in Practice“, you will receive first-hand information about current products, services, references and worthwhile industry insights.